Read first
Why fire officers look harder at cafes now
The interior designer has drawn a mezzanine with bean-bag seating and a single wooden staircase, the kind of corner that photographs well. Then the fire consultant asks how forty people get out of there if the kitchen catches fire. Since the rooftop restaurant fire at Kamala Mills in Mumbai in December 2017 and later fires in Delhi and Kolkata eateries, fire officers and courts have looked hard at rooftops, mezzanines, bamboo and fabric decor and blocked exits. Design for that conversation before you build, not after.
When a cafe needs a fire NOC
There is no single national rule; each state's fire service act and the building bye-laws decide. Across the cities we checked, the same three questions decide it:
- How many people can the cafe hold? Fire services count the floor area open to customers, not just your chairs. A cafe with 30 seats and room to stand at the counter can count as more than 50 people.
- Where is it in the building? Basements, upper floors of buildings above the height your state treats as high-rise, terraces and rooftops bring stricter rules, often a NOC regardless of size.
- What is the building? In a mall, an office tower or a hotel, the building holds a fire NOC and your outlet's fit-out must be approved under it. A standalone ground-floor shop is judged on its own.
What the rule is in the cities we checked
| City or state | When a cafe needs fire clearance | Who issues it |
|---|---|---|
| Delhi | 50 people the premises can hold: places that can hold that many are assembly buildings under the fire service rules | Delhi Fire Service |
| Mumbai | Fire clearance is separate from the BMC eating house licence (Issued by the BMC ward office under section 394 of the Mumbai Municipal Corporation Act, for health and hygiene only; the fire NOC comes separately from the Chief Fire Officer, and the licence does not certify that the building is legal); the fire brigade sets conditions on exits, extinguishers and permitted fuel | Mumbai Fire Brigade (Chief Fire Officer) |
| Telangana (Hyderabad) | Assembly buildings on a plot over 500 sq m or 6 m and taller (Plot over 500 sq m, or building 6 m or taller) | Telangana State Disaster Response and Fire Services |
| Other states | Check your state fire service act and the building bye-laws; most follow the National Building Code's idea of an assembly building | State fire service |
Delhi's rule has been tested in court. In 2026 the Delhi High Court let small first-floor restaurants in Khan Market keep running with guests capped below the threshold and extra safety conditions, rather than shutting them. A cap on numbers is a real option for a small upper-floor cafe, but you have to keep to it.
Gas: the rule that catches kitchens
Count every cylinder on the premises, full or in use, including spares stored in the back.
- Keep cylinders outside the kitchen in a ventilated cage or a separate gas bank with a manifold, not under the counter. Inspectors fail cylinders in the dining area or under stairs.
- Use commercial cylinders, not domestic ones; domestic cylinders in a business are an offence under the LPG control rules and a common finding in raids.
- If you switch to piped gas or induction, ask whether your city has eased fire requirements for cleaner fuels; Mumbai did so for bakeries and restaurants in 2025.
What the fire officer checks
Even a small cafe that needs no NOC should meet this list. The municipal licence conditions in most cities, including Mumbai's, require working fire-fighting equipment and clear exits, and a fire in a cafe without them is the owner's liability.
How to get it
- Hire a fire safety consultant or an architect familiar with your city's fire service at the drawing stage. They size exits and equipment and prepare the application drawings.
- Apply online on your state fire service portal with the layout, the building's details, the occupancy certificate and the landlord's documents.
- Install equipment from an approved supplier, keep the bills, and book the inspection when the fit-out is nearly complete.
- Fix anything the inspector lists and get the certificate. Display it if your city asks you to; Mumbai's civic body has pushed eateries to show it at the entrance.
- Renew it on time and keep refill and service records for extinguishers.
If you are small, medium or large
- A small ground-floor counter: usually no NOC, but keep extinguishers, a clear exit and gas outside the kitchen. The trade licence inspector will look.
- A medium cafe of 30 to 50 seats: you are near the line. Count capacity the way the fire service does before you finalise seating; dropping a few seats can keep you under it, but only if you stay under it every day.
- A large cafe, a rooftop or a basement: plan for a full NOC, two exits and possibly sprinklers or a fire alarm. Budget for it in fit-out, not as an afterthought.
What usually goes wrong
- Adding a terrace or mezzanine after the NOC, which changes the capacity and the exits.
- Counting chairs instead of floor area, then finding the fire service counts more people.
- Storing spare cylinders in the kitchen or under the stairs.
- Choosing decor for photographs, then failing the inspection on flammable materials.
- Relying on the landlord's or the mall's NOC without checking whether it covers your fit-out.
- Letting extinguishers expire after the first year.
This page is general information, not legal or safety advice. Fire rules differ by state and change after major fires; take advice from your local fire service or a qualified consultant.
Questions people ask
Does a 30-seat cafe need a fire NOC?
Often not on seats alone, but it depends on how your state counts capacity and where the cafe is. In Delhi the line is 50 people the premises can hold, counted by floor area as well as seats. A 30-seat cafe in a basement or on a rooftop may need one regardless.
Is a fire NOC needed for a rooftop cafe?
Almost always. Rooftops and terraces raise questions about exits and the building's structure, and several cities have cracked down on unauthorised rooftop eateries after fires. Check that the building's sanction allows the terrace to be used at all.
How long does a fire NOC take?
Commonly two to six weeks, most of it waiting for the inspection. Starting at the drawing stage avoids rework.
Can I keep four commercial cylinders in my cafe?
Four 19 kg cylinders hold 76 kg of gas, under the 100 kg of gas at a time (about five 19 kg commercial cylinders) limit. Keep them outside the kitchen in a ventilated area, and check whether your fire service or gas supplier sets a lower limit.
This is general information, not legal advice. Rules and fees change and differ by state and city; confirm with the department or a professional before you apply.
Where these numbers come from
- LPG a cafe can keep without a gas cylinder storage licence: 100 kg of gas at a time (about five 19 kg commercial cylinders) (all India, Gas Cylinders Rules 2016 rule 44; above this you need a storage licence from PESO; your fire officer and gas supplier may set lower limits for a kitchen, and cylinders inside the dining area are a common inspection fail). Official source: PESO, FAQ on approvals and licences under the Gas Cylinders Rules 2016 (2024), LPG storage, checked 9 November 2026.
- When a Delhi cafe needs a fire safety certificate: 50 people the premises can hold (Delhi; a restaurant or cafe that can hold 50 or more people counts as an assembly building and needs Delhi Fire Service clearance; the fire service counts floor area, not just chairs; other states set their own thresholds). Official source: Delhi Fire Service Rules 2010, rule 27 (India Code), checked 9 November 2026.
- Mumbai eating house licence: Issued by the BMC ward office under section 394 of the Mumbai Municipal Corporation Act, for health and hygiene only; the fire NOC comes separately from the Chief Fire Officer, and the licence does not certify that the building is legal (Mumbai (BMC area), policy in force from 1 March 2016; other Maharashtra cities license eating houses through their own municipal corporations). Official source: Municipal Corporation of Greater Mumbai, Public Health Department circular HO/44380/C of 1 March 2016: revised licence procedure and conditions for eating houses under section 394, MMC Act, checked 9 November 2026.
- When an assembly building (which can include eateries) needs a fire NOC: Plot over 500 sq m, or building 6 m or taller (Telangana). Official source: Telangana Fire Services: buildings and premises which require or do not require a fire NOC, checked 7 November 2026.
Fees, rates and rents change. Check the official source before you pay or sign anything.
Legal and licences · Cafe
More on legal and licences for a cafe
9 pages on this. You are on number 5.
- In what order should I apply for cafe licences, and how long does each take?
- Which licences transfer when a cafe changes hands?
- Does my cafe need an eating house licence, and which cities ask for one?
- Does my cafe need a fire NOC?
- What GST does a cafe charge, and should it take the composition scheme?
- Do I need a licence to play music in my cafe?
- Do I need permission for my cafe's signboard?
- Can I put tables outside my cafe? What permissions do I need?
Reading about it is one thing; doing it in your cafe is another. If you'd like a hand getting your licences and paperwork right, tell us where you are and a person will reply, free.
Get help with this ↓What now?
Where are you?
One tap, and we point you to the right next step.