Read first
The extinguisher with the expired tag
An inspector walks into a guest house on a Tuesday. The extinguisher on the first floor is in date but sits behind a stack of chairs, the one in the kitchen expired in March, a cylinder is under the stairs and the panel in the lobby is open with a duster on top. Nothing was on fire. The owner is still given a notice.
Fire and electrical faults are the failures that end lives and businesses. The checks cost almost nothing, and the record shows the inspector that you do them.
What inspectors and courts look at
The Karnataka High Court order of 10 September 2026 (as read from the press and the order copy) lists, for fire safety: clearance, extinguishers, alarms, smoke detectors, emergency lighting, exits, signage, fire doors, kitchen and gas safety and vehicle access. It adds that exits and stairs must not be obstructed, that panels, earthing and circuit protection must be sound, and that gas must not be kept in staircases or corridors. The fire authority sets requirements by height, area, occupancy and use. See fire and building safety for a stay.
The checks, by how often
| When | What | Fix if |
|---|---|---|
| Every day | Exits, corridors and stairs clear; main gate or fire exit not locked from the outside at night; kitchen gas off after service; no cooking in rooms | Anything blocks the way out |
| Every day | Night person knows the emergency numbers and where the main switch and gas shut-off are | They do not |
| Every month | Each extinguisher: mounted, in reach, pressure gauge in the green, tag and date | Gauge not green, tag expired, hidden or blocked |
| Every month | Smoke alarms and emergency lights tested with a button or switch-off | A battery or a light is dead |
| Every month | Electrical panels dry, covered and clear; no loose or hot sockets; no extension-cord chains; geysers on a switch and in working order | Heat, burning smell, sparking, wet panels |
| Every month | Gas: hoses unbroken, regulators dated, cylinders upright, chained and ventilated; no gas in staircases or corridors; soap test on joints | Any smell or loose joint; stop use and call the dealer |
| Every month | CCTV playback test and entry log; first-aid kit stocked | Camera or log fails |
| Every year | Fire equipment service by a qualified person; wiring and earthing check by an electrician; look at the structure for cracks and damp; pest control schedule | Any item flagged |
For stays that cook, see setting up a stay's kitchen and storing LPG safely. For emergencies at night, see what to do when someone falls ill or has an emergency.
Keep a record that works for you
- A one-page log on the wall or in a folder: date, check, initials, problem, fixed on.
- Photograph each extinguisher's tag and each panel after the monthly check.
- Keep servicing receipts and electrician's notes with the licence papers.
- Show it to the first inspector who asks, in the order of the table above.
- Review after any incident and add a check that would have caught it.
If you are small, if you are large
Small. A family stay needs the monthly list done on one Sunday, with two extinguishers, a smoke alarm and a first-aid kit. The record is a line in a notebook.
Large. Assign each check to a named person, add alarms and emergency lights per floor, run an evacuation drill twice a year and have an engineer look at the structure of older or taller buildings.
What usually goes wrong
- Extinguishers bought once and never checked.
- A fire exit locked at night because of theft worries.
- Cylinders in a staircase, or stored indoors for convenience.
- Daisy-chained extension cords in rooms, and geysers left on.
- A log that is filled in all at once before an inspection.
- No one besides the owner knows where the main switch and gas shut-off are.
Apply it to your own case
If you tell us your building and number of floors, we can help you build a monthly list that fits it.
Questions people ask
How often should extinguishers be serviced?
Check them monthly and have them serviced at least yearly by a qualified person, or as the tag and your fire authority say.
Do I need a fire alarm in a small guest house?
Requirements depend on height, size and use, and your fire authority. Smoke alarms are cheap and sensible in any stay.
Can I keep a spare cylinder inside?
Keep cylinders upright and ventilated, outside living areas and never in a staircase or corridor, as the Karnataka court order says.
Who should do the electrical check?
A licensed electrician, yearly, and a monthly look by you for heat, burning smells and loose sockets.
Operations · Stays
More on operations for a stays
8 pages on this. You are on number 2.
- What should I record when someone checks in: ID, address, emergency contact, times?
- What fire, gas and wiring checks should I do every month in a stay?
- How do I log complaints and promise fix times so small problems do not become reviews?
- What do I do when someone staying with me falls sick or has an emergency at night?
- How do I run a stay when the water runs short in summer?
- Should I put sub-meters on each room, and how do I recover the power bill fairly?
- Where can I put CCTV in a stay, where is it banned, and how long do I keep the footage?
- A notice or an inspector has arrived at my stay. What do I do first?
Reading about it is one thing; doing it in your stays is another. If you'd like a hand running it smoothly day to day, tell us where you are and a person will reply, free.
Get help with this ↓What now?
Where are you?