Stays · 4 min read

How much power load and backup does a stay need?

The short answer

Add up what can run at the same time at the busiest hour, in the hottest month: every geyser, AC, pump, kitchen appliance, lift and light, then compare it with your sanctioned load and your wiring. Choose a backup that carries lights, fans, Wi-Fi, CCTV, the water pump and emergency lighting, not necessarily the ACs. Find out which tariff class you are billed under, because a stay that becomes commercial in the power company's eyes pays more per unit and a higher fixed charge.

Not sure about your case? Ask an expert, free ↓

The geysers and the trip switch

On the first cold morning, eight geysers go on within ten minutes of each other and the main switch trips. The warden resets it twice, the third time nothing happens, and the building has no hot water, no fans and no Wi-Fi at the hour guests are leaving for work. The wiring was fine for the day it was installed. The load had grown with every room and every geyser.

Work out your load, step by step

  • List every appliance by room and common area: lights, fans, geysers, ACs, coolers, pumps, kitchen equipment, refrigerators, washing machines, chargers.
  • Write each one's rated power from its label, in watts or kilowatts.
  • Mark what runs together at the peak: all geysers at 7 am, all ACs on a summer evening, the pump and the kitchen at lunch.
  • Add the peak group and compare with the sanctioned load on your meter and the capacity of your wires and main switch.
  • Ask an electrician to confirm the wiring and earthing can carry it and to put loads on separate circuits.

If your peak is above the sanctioned load, apply for an increase with the power company, and ask what it costs and how long it takes before you promise AC to guests.

Tariff class: domestic or commercial

Power companies bill houses and businesses at different rates. One unofficial calculator for Bengaluru's power company put domestic ₹4.15 to ₹8.20 a unit against commercial ₹8.75 to ₹11.80; fixed charge ₹110 against ₹230 per kW; plus fuel adjustment ₹0.24 a unit and 9 percent duty (unofficial calculator, rates effective 1 April 2025); the ₹0.56 true-up applies from May 2026. A stay in a house may be billed domestic until the company reclassifies it, and then the bill jumps. See property tax and power tariff class for which class you are likely to face.

Large PGs also report big bills: ₹25,000 to ₹35,000 a month earlier, now up by ₹8,000 to ₹10,000 (about ₹33,000 to ₹45,000, our sum), as stated by a PG owners' association president in June 2025. Treat it as a sign of scale, not as a forecast for your stay.

Backup: what to carry and what to leave

Operator practice. Size the inverter or generator to the 'yes' items with a margin.
ItemOn backup?Why
Lights and fansYesBasic comfort and safety
Wi-Fi router and CCTV recorderYesResidents and records; recording must continue
Water pumpYesA dry tank follows a power cut
Emergency lights, alarms, gate lockYesSafety
GeysersNo, or only someHeavy load
ACNo, unless a generator is sized for itVery heavy load
Kitchen refrigeratorYesFood safety

An inverter and battery suit a small stay with short cuts. A generator suits larger buildings or places with long outages. Ask your electrician to size it, and check noise and fuel storage rules so the neighbours and the society do not object. See power and fire safety.

If you are small, if you are large

Small. A few rooms in your house: check what your wiring carries, put geysers on timers and use an inverter for lights, fans and Wi-Fi.

Large. Hire an electrical engineer to design circuits per floor, plan a load increase, specify the backup and fit sub-meters. See sub-meters and power recovery.

What usually goes wrong

  • Adding geysers and ACs room by room without checking the load.
  • No separate circuit for the kitchen and geysers.
  • An inverter that carries ACs and drains in half an hour.
  • A generator beside a bedroom window.
  • Learning that the tariff class changed only when the bill arrives.
  • A CCTV recorder with no backup, so recording stops in a cut.

Apply it to your own case

If you share your appliance list and building, we can help you check the load and choose backup.

Questions people ask

How much load does a guest house need?

It depends on geysers, AC and the kitchen. Add what runs together at the peak and compare it with your sanctioned load; an electrician should confirm the wiring.

Inverter or generator?

An inverter for lights, fans, Wi-Fi, CCTV and the pump in a small stay; a generator for larger buildings or long outages. Check noise and fuel rules.

Will my power bill change if I run a stay?

It may, if the company reclassifies the connection as commercial. Ask before you start and plan for it.

Should the AC run on backup?

Usually not. It is the heaviest load and a poor use of a battery.

Where these numbers come from

  1. BESCOM domestic against commercial tariff, from an unofficial calculator: domestic ₹4.15 to ₹8.20 a unit against commercial ₹8.75 to ₹11.80; fixed charge ₹110 against ₹230 per kW; plus fuel adjustment ₹0.24 a unit and 9 percent duty (unofficial calculator, rates effective 1 April 2025); the ₹0.56 true-up applies from May 2026 (Karnataka, unofficial calculator, April 2026). Reported: An unofficial BESCOM tariff calculator, BESCOM domestic against commercial tariff, from an unofficial calculator, checked 14 November 2026.
  2. Monthly electricity bill of a PG of about 150 occupants, Bengaluru: ₹25,000 to ₹35,000 a month earlier, now up by ₹8,000 to ₹10,000 (about ₹33,000 to ₹45,000, our sum), as stated by a PG owners' association president in June 2025 (Bengaluru PG). Reported: The News Minute, Monthly electricity bill of a PG of about 150 occupants, Bengaluru, checked 14 November 2026.

Fees, rates and rents change. Check the official source before you pay or sign anything.

Place and setup · Stays

More on place and setup for a stays

5 pages on this. You are on number 4.

  1. What should I check in a building before I rent or convert it into a stay?
  2. What happens to my stay if its demand rests on one employer, one college or one season?
  3. How many bathrooms and how much water does a stay need per bed or room?
  4. How much power load and backup does a stay need?
  5. How do I set up a stay's kitchen and store LPG cylinders safely?

Reading about it is one thing; doing it in your stays is another. If you'd like a hand choosing and setting up the right place, tell us where you are and a person will reply, free.

Get help with this ↓

What now?

Next question · 12 of 15 in The building and its fittingsShould I put sub-meters on each room, and how do I recover the power bill fairly? →

Where are you?

One tap, and we point you to the right next step.

Menu

Read

Ask an expert Ask an expertFree, real peopleHub
Ask an expert