Read first
Why plan the kitchen first?
The equipment dealer sends a drawing on WhatsApp: tandoor here, ranges there, a hood the width of the wall. It looks fine. Nobody has asked where the dish tray goes when the dining room is full or where the smoke will leave the building. A kitchen is the part of a restaurant that is hardest to change after the tiles, the plumbing and the ducts are in. The kitchen and back-of-house take about 35–45%, and kitchens, stores and washrooms occupy 30–40% of total area, so a mistake here is the costly one.
For a small restaurant the equipment supplier often draws the layout. That is fine as a starting point, but get it checked by someone who has run a kitchen of your menu, because a supplier's layout is built to sell equipment, not to move plates.
How should the kitchen flow?
Plan the zones as a line, in the order food moves, and keep clean and dirty apart:
- Receiving, with a door that opens to the delivery side, a place to weigh and check, and no walk through the cooking line.
- Dry store and cold store, near receiving, so the cook does not cross the kitchen to fetch.
- Prep, with vegetables and raw meat on separate tables and boards.
- The cooking line, under the hood: tandoor, ranges, wok, fryer, griddle, in the order your top dishes use them.
- The pass, where plates meet the captain, with a view of the floor.
- Wash-up (pot wash and dish wash), with a route from the dining room that does not cross the pass.
Then add entry, bar, toilets and the cashier. Put toilets near existing plumbing. The standing advice from planners is to work the kitchen out first and fit the dining room to what is left, not the other way round. See how big a restaurant should be for the area split and the equipment list for what goes on the line.
What does the exhaust system need?
An exhaust system is four parts designed together: the hood over the line, the duct to open air, the fan, and a way for fresh air to come back in. Get any one wrong and the kitchen is smoky, hot and loud, and staff leave.
- Hood with baffle filters. IS 18271:2023, the Bureau of Indian Standards code for fire safety in commercial kitchens, says mesh filters are not appropriate for moderate to heavy grease cooking. It applies to kitchens in centrally air-conditioned buildings such as hotels, food courts, malls and restaurants, and is advised for others. Use baffle filters you can pull out and degrease.
- Duct. Galvanised or stainless steel, not aluminium flex, thickness of at least 1.2 mm in one trade guide, with airtight joints, access panels for cleaning and drip troughs at low points. In Mumbai's codified rules the outlet must be at least a metre above the structure.
- Make-up air. An exhaust with no make-up air starves the burners of oxygen, pulls smells in from the dining room and makes doors hard to open. Plan a fresh-air unit with the hood.
- Sizing. Dealer listings show typical sizes, but do not size from a catalogue. Get the hood, fan and duct sized by the supplier from your actual cooking line and the drawing of the duct route, and ask for the airflow figure in writing. No sourced rule of airflow per foot of hood was found.
If the exhaust route is not agreed with the landlord, none of this matters. Check landlord permissions before you pay for the hood.
Fire suppression and separation
The 2026 national building code asks for the kitchen to be separated by a 120 minutes fire-rated enclosure, which can be reduced where suppression is installed; LPG kitchens are barred from basements. On suppression, IS 18271 says: Required in kitchens of centrally air-conditioned buildings; advised elsewhere. A fire consultant's reading is that no national rule makes a wet-chemical system mandatory for every restaurant, and your state fire officer decides, so ask before you buy. See fire safety and grease trap and fire NOC.
Hood and duct fires are the most common kitchen fire, caused by grease building up above the flame. The cure is to clean on a schedule: the standard lists how often exhaust grease should be inspected (Solid fuel monthly; high-volume (24-hour, charbroil, wok) quarterly; moderate semi-annual; low annual), and trade guidance puts contractor cleaning at Quarterly for fryer and tandoor kitchens, semi-annual for lighter ones.
What do I plan beyond the hood?
- Gas. A place for the cylinder bank outdoors, a piped route, a leak detector and an automatic shut-off. See LPG prices and use.
- Drains and grease trap. Floor drains in the wet areas, a gradient to the trap and room to clean it.
- Cold chain. Put the fridges where the cooks use them, with a clear door swing and room for the compressor to breathe.
- Electricals. Sockets and cables for every machine at the right height; ask the equipment dealer for the connected load.
- Floors and walls. Non-slip floors with a slope to drains, and cleanable wall surfaces; see kitchen hygiene rules.
- Light and heat. The line gets hot; plan ventilation and light for staff who stand there eight hours.
What usually goes wrong
- Budgeting for the dining room and finding the kitchen takes 35–45%.
- A hood narrower than the cooking line, so heat and smoke escape at the sides.
- An exhaust without make-up air, retrofitted after the tiles are down.
- A duct route nobody agreed with the building.
- The dish return crossing the pass, so dirty plates meet clean ones.
- Choosing mesh filters because they are cheaper, then clogging them with grease.
- Letting the equipment dealer be the only designer.
Apply it to your own case
Write down your ten top-selling dishes and the equipment each needs, then draw the line in the order a ticket moves. Ask two suppliers for hood, duct and make-up air drawings and a written airflow figure, and ask your fire consultant what your state expects for suppression. Tell us your city, menu and seat count and we can help check the plan before you spend.
If you are a tiffin place or a dhaba
A tiffin kitchen separates a wet batter room from the frying and tawa heat; see the tiffin line. A highway dhaba adds a generator and a borewell to the site plan; see land and permissions.
Questions people ask
Do I need baffle filters in a restaurant hood?
IS 18271:2023 says mesh filters are not appropriate for moderate to heavy grease cooking, which covers most Indian kitchens. It applies to kitchens in centrally air-conditioned buildings and is advised for others.
How often must the duct be cleaned?
IS 18271 lists inspection of exhaust grease (Solid fuel monthly; high-volume (24-hour, charbroil, wok) quarterly; moderate semi-annual; low annual), and trade guidance puts contractor cleaning at Quarterly for fryer and tandoor kitchens, semi-annual for lighter ones. State fire rules may be stricter; ask your fire officer.
Do I need fire suppression over the stove?
IS 18271 requires automatic suppression in kitchens of centrally air-conditioned buildings and advises it elsewhere. No national rule makes it mandatory for every restaurant, so ask your state fire officer.
Who should design my kitchen?
A kitchen designer or consultant who has built kitchens for your menu, working with the equipment supplier. Do not let one drawing from a seller be the only plan.
Where these numbers come from
- Minimum duct thickness: 1.2 (India; vendor guide). Reported: BSHoreca, fire safety requirements for commercial kitchens, checked 14 November 2026.
- Fire-rated separation for a commercial kitchen: 120 minutes (India, national building code 2026; LPG kitchens not allowed in basements). Reported: Flamekite, fire NOC for restaurants (NBCS 2026 clauses 4.5.3.6 and 4.7.9), checked 14 November 2026.
- Automatic fire suppression over grease-laden cooking equipment: Required in kitchens of centrally air-conditioned buildings; advised elsewhere (India, IS 18271:2023 clause 1.3). Official source: BIS, IS 18271:2023 (commercial kitchen exhaust and fire protection; archive.org copy), checked 14 November 2026.
- How often to inspect kitchen exhaust grease: Solid fuel monthly; high-volume (24-hour, charbroil, wok) quarterly; moderate semi-annual; low annual (India, IS 18271:2023 Table 1). Official source: BIS, IS 18271:2023 Table 1 (archive.org copy), checked 14 November 2026.
- How often a contractor cleans hood and duct: Quarterly for fryer and tandoor kitchens, semi-annual for lighter ones (India; vendor guidance, state fire rules not opened). Reported: ProKitchens, exhaust hood cleaning in India, checked 14 November 2026.
Fees, rates and rents change. Check the official source before you pay or sign anything.
Place and setup · Restaurant
More on place and setup for a restaurant
14 pages on this. You are on number 2.
- How do I pick a location for a restaurant?
- How do I plan a restaurant kitchen layout and exhaust so it passes inspection?
- Mall, food court, high street, office area or residential: where does a restaurant do well?
- What equipment does a restaurant really need on day one, and what does it cost?
- How do I judge footfall, catchment and competitors for a restaurant before I sign?
- How much restaurant kitchen equipment costs in India, item by item
- How big should my restaurant be, and how many seats do I need?
- What fire safety, grease trap and gas safety does a restaurant kitchen need?
Reading about it is one thing; doing it in your restaurant is another. If you'd like a hand choosing and setting up the right place, tell us where you are and a person will reply, free.
Get help with this ↓What now?
Where are you?
One tap, and we point you to the right next step.