Hire a licensed electrical supervisor first, then a survey and design engineer, then a trained installation crew. Everything else, such as DISCOM liaison, accounts and AMC technicians, can start as part of someone's role or be bought in per task. Most rooftop installers are three to eight people for a long time, so the order and the contracts matter more than the headcount.
Pay figures below are monthly estimates for 2026 and vary by city and experience. Labour, licence and contract rules differ by state, so confirm locally.
The roles in the order you actually need them
| Order | Role | What they own | When |
|---|---|---|---|
| 1 | Licensed electrical supervisor | The licence that lets your firm do electrical work, plus on-site safety and final connections | Before the first job, if you are not licensed yourself |
| 2 | Survey and design engineer (often a diploma or B.E. in electrical) | Site survey, string design, bill of materials, proposals, shading judgement | Within the first few jobs, if you are not an engineer |
| 3 | Installation team lead and two to three helpers | Structure assembly, panel mounting, cable routing, earthing | When you have two or more jobs a month |
| 4 | DISCOM and portal liaison | Application entries, follow-up at the DISCOM office, meter and inspection dates | When paperwork starts delaying commissioning |
| 5 | Sales and customer executive | Home visits, quotes, follow-ups, referrals | When the owner can no longer both sell and supervise |
| 6 | AMC and service technician | Panel cleaning rounds, inverter faults, annual checks | Once about 40 to 60 systems are under contract (an estimate) |
| 7 | Accounts and stores | GST invoices, supplier payments, serial-number stock register | When volume gets past what you can keep in sheets |
If you come from an electrical background, you may hold roles 1 and 2 yourself and hire only the crew. If you come from sales, hire the licensed supervisor and engineer first and pay them well; the cost of one wiring mistake exceeds a year of the salary difference.
What each role is paid
| Role | Metro | Tier-2 city | Notes |
|---|---|---|---|
| Licensed electrical supervisor | ₹35,000–60,000 | ₹25,000–40,000 | Many are part-time consultants for several firms; confirm the licence is valid in your state |
| Design and survey engineer | ₹30,000–55,000 | ₹20,000–35,000 | Fresh graduates with solar-design course training are cheaper but need a senior to review designs |
| Installation team lead | ₹22,000–35,000 | ₹16,000–26,000 | Skilled, experienced at height |
| Installation helper | ₹14,000–20,000 per month, or ₹600–900 a day | ₹11,000–16,000 per month, or ₹450–700 a day | Daily-wage helpers are common; training and safety kit are your cost |
| DISCOM liaison | ₹20,000–32,000 | ₹14,000–24,000 | Knowledge of your DISCOM's portal and field staff matters more than a degree |
| Sales executive | ₹18,000–30,000 plus incentive | ₹14,000–22,000 plus incentive | Incentive per kW sold works better than a pure salary |
| AMC technician | ₹16,000–26,000 | ₹12,000–20,000 | Needs a bike and a phone allowance |
Where to find solar-specific people
- Local electricians and wiremen already working on residential jobs. Teach them DC safety and structure work rather than hiring cold.
- ITI and polytechnic electrical departments, where final-year students often seek apprenticeships. Apprenticeship rules and stipends are set under the Apprentices Act; confirm the current process locally.
- Solar skilling courses: training programmes such as the Suryamitra scheme and NSDC-linked Skill Council for Green Jobs courses have existed; their current status and fees are unverified, so check before relying on them.
- Larger EPC firms and former employees who know commercial-scale practice; some freelance between projects.
- Supplier and inverter-maker service engineers, useful for commissioning training, sometimes available as freelance support.
- Local job groups on WhatsApp and Facebook, where crew leaders list their availability.
Vet them with a task, not a CV
Solar skills show up in how someone handles a real connector or a real roof. A short test, paid for their time, saves months.
- Installer test: give them an MC4 pair, a cable and the crimper. Watch crimp, seat and pull-test. Ask why a crimped lug on an earth strip must be tight and tinned if needed.
- Supervisor test: show a single-line diagram of a 3 kW system and ask where the DC isolator, SPDs, MCBs and earthing connect and why.
- Engineer test: give them a customer's six-month bill history and a roof photo, ask for a proposed system size and the questions they would ask the customer. Look for shading and sanctioned-load awareness, not a rushed number.
- Height check: observe how they set up the harness and anchor, and whether they ask about the roof surface. Do not hire anyone who treats the harness as optional.
- Reference call: ask a previous employer about attendance and honesty on site; materials walk off in this trade.
Salaried, daily wage or freelance
| Mode | Good for | Risk and tip |
|---|---|---|
| Salaried with PF and ESI as applicable | Supervisor, engineer, liaison, sales | Statutory contributions depend on headcount and wage thresholds; confirm with a CA or labour department |
| Daily-wage helpers | Installation labour on busy weeks | Safety training and insurance still apply; keep attendance and payment records |
| Per-kW or per-job piece rate to a crew contractor | Mounting and cabling | Quality varies; hold a retention (for example 10 percent for 30 days, an illustrative term) until commissioning |
| Freelance design or consulting engineer | Commercial designs and electrical sign-off | Agree who owns the drawings and who is liable for errors in writing |
| Outsourced AMC contractor | Customers outside your usual area | Warranty responsibility stays with you; define response times |
Employment classification, contractor liability and labour registrations vary by state. Confirm with the labour department and a CA. This is not legal advice.
Contracts and habits that protect you
- Written appointment letter with duties, pay, notice period and a clause on handling customer data and materials.
- Safety undertaking: crews sign that they have been briefed on harness use, DC hazards and lock-out practice.
- Material accountability: every module and inverter serial number goes into a register against a job; any shortage is traced to a site.
- Non-solicitation: an engineer who leaves with your customer list is a common loss. A clause helps but enforceability varies, so take legal advice.
- Training budget: a day of manufacturer or supplier training for every new team lead is cheap insurance.
Once a crew is stable and you are chasing leads, see how to get solar customers for the demand side, and the playbook overview for where hiring fits in the first year.
Before you hire anyone
More on starting a solar installation business
- Start hereThe full playbook →Models, licences, startup costs and the steps to your first customer.
- Go deeperWhat to buy →Testers, safety gear and a vehicle first; panels per job, not on the shelf; what to skip.
- Go deeperGetting customers →Bill-based quotes, society demos, referrals and local search; launch pricing; AMC for retention.
- Go deeperFinding suppliers →Modules, inverters, structures, cable and BOS: how to find, vet and negotiate with each.
Questions people ask
Do I need to be an electrical engineer myself?
No, but your firm needs the right electrical contractor licence and a qualified supervisor, as required by your state's electrical licensing authority. Many founders come from sales or trading and hire a licensed supervisor and an engineer. Confirm the exact licence conditions with the electrical inspectorate or licensing board in your state before taking jobs.
How many people do I need for a three-kilowatt home installation?
A common crew is a team lead and two or three helpers for one to two days, with a supervisor visiting for connection and testing. Exact numbers depend on roof access, structure type and weather. Keep a minimum of two people at height at all times, and never send one person to a roof alone.
Should I train fresh helpers or hire experienced ones?
Do both. Hire an experienced team lead who has worked on solar or electrical sites, and train helpers from local ITI students or electrician apprentices. Pay for safety gear and proper training, because injuries and badly crimped connectors cost far more than the training. Check apprenticeship rules locally before enrolling anyone.
Is it safer to subcontract installation to crew contractors?
It saves fixed cost but reduces control over quality and safety. If you subcontract, pay per job with a retention until commissioning, supply the critical items like connectors yourself, inspect every site before sign-off, and remember that warranty and customer responsibility stay with you, not the contractor.
What is a fair incentive structure for sales staff?
Pay a modest base plus an incentive per kW installed rather than per lead, so staff care about jobs that complete and get connected. Many installers pay after the customer's final instalment. These are practices, not rules; adjust to your margins and write the terms down before the first sale.
